DateCityStateEmployerBody PartEvent
2021-11-11South EuclidOhAero Controlex GroupFinger(s), fingernail(s)Struck by dislodged flying object, particle
On November 11, 2021, an employee was performing die setup on a hydraulic press. The employee loaded dies into the press and actuated it to verify proper die alignment. The upper and lower dies made contact resulting in die failure. Fragments of the die struck the employee's hand causing a severe laceration and fracture to their index finger. In addition, fragments of metal were embedded into both hands of the employee's hands. There was no machine guarding in place and energy control was not pe
2016-10-19South EuclidOhioUnversity Suburban Health CenterBODY SYSTEMSInhalation of harmful substance-single episode
An employee was hospitalized for respiratory issues after working in the building throughout the day while the elevator was painted from the roof of the building. The paint fumes were pulled into the building via the ventilation system.